Abstract

A rapid, sensitive and automated in-tube solid-phase microextraction-liquid chromatography–mass spectrometry (in-tube SPME/LC–MS) method was developed for the analysis of ten antidepressants in urine and plasma. A hybrid organic–inorganic silica monolith with cyanoethyl functional groups was prepared and used as a sorbent for in-tube SPME. Integration of the sample extraction, LC separation and MS detection into a single system permitted direct injection of the diluted urine or plasma after filtration. Under the optimized conditions, good extraction efficiencies for the targets were obtained with no matrix interference in the subsequent LC–MS. Automation of the sampling, extraction and separation procedures was realized under the control of a program in this study. The total process time was 30 min and only 30 μL of urine or plasma was required in one analysis cycle. Good linearities were obtained for ten antidepressants with the correlation coefficients ( R) above 0.9933. The limits of detection ( S/ N = 3) for ten antidepressants were found to be 0.06–2.84 ng/mL in urine and 0.07–2.95 ng/mL in plasma. The recoveries of antidepressants spiked in urine and plasma were from 75.2% to 113.0%, with relative standard deviations less than 16.5%. The developed method was successfully used to analyze urine sample from ageing patients undergoing therapy with antidepressants.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.