Abstract
An in situ modified Hummers method (without the use of any surfactants) has been used for the deposition of bismuth (Bi) nanoparticles onto the surface of reduced graphene oxide (RGO) sheets. The as-synthesized nanocomposites were characterized by X-ray diffraction (XRD), Fourier transform infrared (FTIR) spectroscopy, Raman spectroscopy, transmission electron microscopy (TEM), thermogravimetry (TG) and differential scanning calorimetry (DSC). The morphology of the RGO/Bi nanocomposites provides a better choice as an electrode material for detection of heavy metal ions due to its better functional properties over the Bi film electrode. Trace analysis of heavy metal ions like Cd+2, Pb+2, Cu+2 and Zn+2 in water is carried out by stripping voltammetric analysis using RGO/Bi nanocomposite as an electrode material. The sensitivity and detection limit of the electrode were quantitatively estimated from the analysis. The three sigma detection limits at different deposition potential for Cd2+, Pb2+, Zn2+ and Cu2+ were obtained as 2.8, 0.55, 17 and 26μgL−1, respectively. Copper detection using Bi-film electrode was a major challenge, which has been resolved using the RGO/Bi nanocomposite electrode.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.