Abstract

ABSTRACT In-situ crack tip pH measurements for corrosion fatigue (CF) cracks in sensitized AA5456-H116 loaded under low loading frequencies show that cathodic polarization has the ability to arrest actively growing stress corrosion (SCC) and CF cracks and produce a local alkaline crack tip pH. A method for measuring crack tip pH in-situ was developed. For AA5456-H116 under a single level of high sensitization, CF experiments while loading in the Paris regime at a loading frequency of 0.1 Hz were conducted under freely corroding conditions and a cathodic polarization of −1.3 VSCE. Results show that under freely corroding conditions the crack actively grows, and the crack tip pH is slightly acidic, while at −1.3 VSCE an alkaline crack tip develops with a pH of 10-12. The findings of this study support the earlier published hypothesis that crack arrest of SCC and low loading frequency CF cracks is due to corrosion-induced blunting after the development of highly alkaline conditions that causes corrosion of the crack tip region blunting and halting the crack.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.