Abstract
A nondestructive evaluation technique has been developed to measure and analyze section loss due to corrosion for anchor rods used in guying steel transmission poles. The anchor guy system tested consists of a steel plate embedded in concrete connected to a steel rod buried in earth and attached to the guy wire from the pole. The method used was ultrasonics and, specifically, the cylindrically guided wave technique (CGWT). Field correlation of the method was verified by digging up and inspecting several rods. This approach has optimized the ultimate replacement and maintenance expense.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.