Abstract
The cyclic stress in lithium-ion battery electrodes induced by repeated charge and discharge cycles causes electrode degradation and fracture, resulting in reduced battery performance and lifetime. To investigate electrode mechanics as a function of electrochemical cycling, we utilize digital image correlation (DIC) to measure the strains that develop in lithium-ion battery electrodes during lithiation and delithiation processes. A composite graphite electrode is cycled galvanostatically (with constant current) in a custom battery cell while optical images of the electrode surface are captured in situ. The strain in the electrode is computed using an in-house DIC code. On average, an unconstrained composite graphite electrode expands 1.41 % during lithiation and contracts 1.33 % during delithiation. These strain values compare favorably with predictions based on the elastic properties of the composite electrode and the expansion of graphite-lithium intercalation compounds (G-LICs). The establishment of this experimental protocol will enable future studies of the relationship between electrode mechanics and battery performance.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.