Abstract

For improving the design of combustors, the knowledge of residence-time distributions (RTD) is important as they influence exhaust gas compositions. Measuring RTDs in combustors is challenging, due to high temperatures, chemical reactions, the presence of particles or corrosive species as well as high turbulence levels. This paper presents a technique for the in situ measurement of RTDs in combustors. Based on tunable diode laser absorption spectroscopy (TDLAS), the temporal evolution of the concentration of tracers is tracked simultaneously at the combustion chamber inlet and outlet. Using either air or mixtures of oxygen and carbon dioxide (oxy-fuel atmosphere) as oxidants, the method is applied to reacting and non-reacting operating conditions in a 20-kWth methane combustor. For reacting conditions, hydrogen chloride is used as a tracer, whereas for non-reacting conditions methane was chosen. Depending on the tracer, for a repetition rate of approximately 2 kHz detection limits of 16–40 ppmV are achieved. For deriving RTDs, low-pass filtering is compared to reactor network modeling. Different RTDs observed for varying operating conditions are discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call