Abstract

SUMMARYMotor torque constant is an important parameter in modeling and controlling a robot axis. In practice this parameter can vary considerably from the manufacturer's specification, if available, and this makes it desirable to characterise individual motors. Traditional techniques require that the motor can be removed from the robot for testing, or that an elaborate technique involving weights and pulleys be employed. This paper describes a novel method for measuring the torque constant of robot servo motors in situ and is based on the equivalence of motor torque and back EMF constants. It requires a very simple experimental procedure, utilizes existing axis position sensors, and eliminates effects due to static friction and joint cross coupling. A straightforward extension to this approach can provide a measurement of motor armature impedance. Experimental results obtained for a Puma 560 are discussed and compared with other published results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.