Abstract

It is well known that the coefficient of thermal expansion (CTE) has substantial effects on behavior and performance of concrete structures. In this study, a time-dependent variation of CTE in hardening concrete was examined based on a series of field experiments using a device called impervious non-stress cylinder (INC). The results showed consistent trends: (1) the CTE at the time of setting is about twice as high as the CTE in the stabilized stage and (2) after the CTE’s initial sudden drop, it starts to slightly increase for a certain period of time and then stabilizes. The present study also quantitatively investigated the effect of time-dependent CTE variation on thermal stress developments. The results revealed that the effect of CTE’s time-dependent variation is non-negligible; rather, it may be of great importance for accurate assessments of early-age cracking potential and the later-age behavior and response of concrete structures.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.