Abstract

• Compare SLM of Ti/Mo and Ti/Mo 2 C powder mixtures to prepare Ti-Mo biomaterials. • Explore thermal mechanisms behind metallurgical differences of Ti-Mo biomaterials. • Reach low moduli in both in-situ Ti-7.5Mo-2.4TiC composites and Ti-7.5Mo alloys. • Reach 12.1% higher strength in Ti-7.5Mo-2.4TiC composites than Ti-7.5Mo alloys. • Reach a 36% lower wear rate in Ti-7.5Mo-2.4TiC composites than Ti-7.5Mo alloys. Ti-Mo alloys/composites are expected to be the next-generation implant material with low moduli but without toxic/allergic elements. However, synthesis mechanisms of the Ti-Mo biomaterials in Selective Laser Melting (SLM) vary according to raw materials and fundamentally influence material performance, due to inhomogeneous chemical compositions and stability. Therefore, this work provides a comparative study on microstructure, mechanical and wear performance, and underlying thermal mechanisms of two promising Ti-Mo biomaterials prepared by SLM but through different synthesis mechanisms to offer scientific understanding for creation of ideal metal implants. They are (i) Ti-7.5Mo alloys, prepared from a conventional Ti/Mo powder mixture, and (ii) Ti-7.5Mo-2.4TiC composites, in-situ prepared from Ti/Mo 2 C powder mixture. Results reveal that the in-situ Ti-7.5Mo-2.4TiC composites made from Ti/Mo 2 C powder mixture by SLM can produce 61.4% more β phase and extra TiC precipitates (diameter below 229.6 nm) than the Ti-7.5Mo alloys. The fine TiC not only contributes to thinner and shorter β columnar grains under a large temperature gradient of 51.2 K/μm but also benefits material performance. The in-situ Ti-7.5Mo-2.4TiC composites produce higher yield strength (980.1 ± 29.8 MPa) and ultimate compressive strength (1561.4 ± 39 MPa) than the Ti-7.5Mo alloys, increasing by up to 12.1%. However, the fine TiC with an aspect ratio of 2.71 dominates an unfavourable rise of elastic modulus to 91.9 ± 2 GPa, 44.7% higher than the Ti-7.5Mo alloys, which, nevertheless, is still lower than the modulus of traditional Ti-6Al-4V. While, TiC and its homogeneous distribution benefit wear resistance, decreasing the wear rate of the in-situ Ti-7.5Mo-2.4TiC composites to 6.98 × 10 −4 mm 3 N −1 m −1 , which is 36% lower than that of the Ti-7.5Mo alloys. Therefore, although with higher modulus than the Ti-7.5Mo alloys, the SLM-fabricated in-situ Ti-7.5Mo-2.4TiC composites can expect to provide good biomedical application potential in cases where combined good strength and wear resistance are required.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call