Abstract
This paper presents the in situ characterization of microscale poly(dimethylsiloxane) (PDMS) springs using silicon-on-insulator-microelectromechanical systems (SOI-MEMS). PDMS samples that were 30 μm long, 20 μm thick, and 6 μm wide were fabricated on-chip along with a test mechanism that included electrostatic comb drive actuators and silicon flexures. The test mechanism allowed for applying strains up to 65%. The in situ test results were compared with results of tests on macroscale samples performed using a dynamic mechanical analyzer. The results imply that the process steps during fabrication initially led to increased crosslinking of the PDMS but that the final release of the structure in buffered hydrofluoric acid decreased the crosslink density, thereby decreasing the stiffness of the PDMS. Several implications of the results on processing PDMS in MEMS are presented. The results of this work are important for the design of MEMS devices which incorporate PDMS as a mechanical material.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.