Abstract

Methods based on sandwich-type electrochemical enzyme immunoassay protocol have been extensively developed for the detection of biomolecules, but most often exhibit low detection signals and low detection sensitivity, and are unsuitable for routine use. In this study, we initially synthesized specially horseradish peroxidase-encapsulated nanogold hollow microspheres (HRP-GHS), and then the prepared HRP-GHS was conjugated to the secondary carcinoembryonic antibody (HRP-GHS- anti-CEA). Carcinoembryonic antigen (CEA), as a model protein, was monitored by using the electrochemical sandwich-type enzyme immunoassay format. Under optimized conditions, the linear range of the immunoassay by using single HRP-labeled anti-CEA (HRP- anti-CEA) as secondary antibodies is 2.5-120 ng/mL with a detection limit of 1.5 ng/mL CEA, while the assay sensitivity by using HRP-GHS- anti-CEA as secondary antibodies is further increased from 0.01 to 200 ng/mL with a lower detection limit of 1.5 pg/mL CEA. The intra- and interassay reproducibility is acceptable. The CEA concentrations of the clinical serum specimens assayed by the developed immunoassay show consistent results in comparison with those obtained by commercially available enzyme-linked immunosorbent assay. This immunoassay system has many desirable merits including sensitivity, accuracy, and little required instrumentation. Significantly, the new protocol may be quite promising, with potentially broad applications for clinical immunoassays.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call