Abstract
In the paper, possibilities of correlation of structural damage and damage of attached artistic assets on multi-leaf stone masonry walls by means of destructive and non-destructive testing (NDT) methods are investigated. Results from two testing campaigns carried out at the University of Genoa and University of Ljubljana are briefly presented. In particular, diagonal tests with different levels of pre-compression and shear tests under different boundary conditions were carried out in Genoa and Ljubljana, respectively. During the tests, different damage limit states (DL) of both masonry walls (SE) and attached plasters (AA) were investigated by means of NDT’s. Two different types of rubble stone masonry were considered (uncoursed random rubble vs. coursed squared rubble). For AA the results are presented in relative form in dependence from the DL of SE. Obtained results are influenced both by the type of test and tested masonry. Results of NDT revealed strong potential and a need for data fusing of both investigated methods for the evaluation of the state of the degradation behind the plaster.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.