Abstract
This paper investigates the behaviour of retrofitted confined masonry walls subjected to in-plane lateral loads. Three full-scale retrofitted wall assemblies with carbon-fibre-reinforced polymer sheets, consisting of a clay masonry panel, two confining columns and a tie beam, were tested under a combination of vertical load and monotonic pushover up to failure. Wall panels had various configurations, namely solid and perforated walls with window and door openings. The walls were compared to the performance of similar un-retrofitted walls. Experimental results showed the ability of the retrofitting scheme to significantly enhance both the load-carrying capacity and displacement ductility of the walls. An analytical investigation was conducted using the finite element method to build a model capable of simulating the response of the tested walls. The validated model was used to conduct a parametric study on untested design configurations. Alternative retrofitting schemes showed either response or economic merits over the experimentally tested one.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Masonry Research and Innovation
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.