Abstract

This paper focuses on the in-plane behaviour of rubble stone masonry with lime mortar strengthened with different solutions. For that, 12 rubble stone masonry wall specimens, with construction features typical of ancient historic buildings of Southern Portugal and Mediterranean countries, were subjected to in-plane quasi-static cyclic tests. The applied retrofit solutions are specific for historic masonry buildings, such as the injection of mortar and FRCM systems, with glass and carbon meshes. The main experimental results obtained are presented through envelope curves, in terms of resistance, deformation capacity, and deformed shapes. Moreover, dissipated energy is also commented on. Horizontal drift results are compared and analysed together with the ones obtained in the literature for equivalent strengthening solutions in masonry walls.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.