Abstract

Abstract. Knowledge of the field of view (FOV) of a remote sensing instrument is particularly important when interpreting their data and merging them with other spatially referenced data. Especially for instruments in space, information on the actual FOV, which may change during operation, may be difficult to obtain. Also, the FOV of ground-based devices may change during transportation to the field site, where appropriate equipment for the FOV determination may be unavailable. This paper presents an independent, simple and robust method to retrieve the FOV of an instrument during operation, i.e. the two-dimensional sensitivity distribution, sampled on a discrete grid. The method relies on correlated measurements featuring a significantly higher spatial resolution, e.g. by an imaging instrument accompanying a spectrometer. The method was applied to two satellite instruments, GOME-2 and OMI, and a ground-based differential optical absorption spectroscopy (DOAS) instrument integrated in an SO2 camera. For GOME-2, quadrangular FOVs could be retrieved, which almost perfectly match the provided FOV edges after applying a correction for spatial aliasing inherent to GOME-type instruments. More complex sensitivity distributions were found at certain scanner angles, which are probably caused by degradation of the moving parts within the instrument. For OMI, which does not feature any moving parts, retrieved sensitivity distributions were much smoother compared to GOME-2. A 2-D super-Gaussian with six parameters was found to be an appropriate model to describe the retrieved OMI FOV. The comparison with operationally provided FOV dimensions revealed small differences, which could be mostly explained by the limitations of our IFR implementation. For the ground-based DOAS instrument, the FOV retrieved using SO2-camera data was slightly smaller than the flat-disc distribution, which is assumed by the state-of-the-art correlation technique. Differences between both methods may be attributed to spatial inhomogeneities. In general, our results confirm the already deduced FOV distributions of OMI, GOME-2, and the ground-based DOAS. It is certainly applicable for degradation monitoring and verification exercises. For satellite instruments, the gained information is expected to increase the accuracy of combined products, where measurements of different instruments are integrated, e.g. mapping of high-resolution cloud information, incorporation of surface climatologies. For the SO2-camera community, the method presents a new and efficient tool to monitor the DOAS FOV in the field.

Highlights

  • The instantaneous field of view (IFOV) of an optical instrument describes the solid angle from which radiation is perceived by a detector

  • The method was applied to two satellite instruments, GOME-2 and OMI, and a ground-based differential optical absorption spectroscopy (DOAS) instrument integrated in an SO2 camera

  • A clear rectangular FOV with expected dimension results from evaluating AVHRR channel 1 images and GOME-2 radiances applying a Gaussian convolution kernel centred at 630 nm (Fig. 7a)

Read more

Summary

Introduction

The instantaneous field of view (IFOV) of an optical instrument describes the solid angle from which radiation is perceived by a detector. If the instrument is moving, averaging the IFOV over the integration time of one measurement yields the field of view (FOV). This study demonstrates that this is a strong simplification and that some spectroscopic instruments feature a more complex FOV. The extent and shape of the FOV are of particular interest in order to register the measured quantity in space. The alignment of the optical components, may change when deploying a satellite instrument in orbit or a ground-based instrument in the field. It is desirable to infer the actual FOV at any time

Methods
Results
Discussion
Conclusion