Abstract

The static in-line calorimeter measures the temperature rise in the walls of a waveguide caused by the attenuation of microwave power flowing through the waveguide. It is simple and inexpensive and can be constructed so that it will fit on waveguide already existing in a microwave system. The device should be reliable because it uses no active circuitry. In addition, few mechanical problems are encountered in its use because the existing waveguide need not be altered. The theory of the device is developed, and two experimental S-band calorimeters using stainless steel waveguide and resistance-wire bridge temperature indicators are described. The measured sensitivity and time constant for both units fall within the experimental error of confirming the theoretically predicted figures.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.