Abstract

In a previous study [1], a commercial PP - based Wood Polymer Composite (WPC) filled with various percentage of white fir fibers (30% – 70% wt.) has been investigated with a parallel plate rheometer in oscillation mode at 170 °C. This temperature has been imposed by the requirement of performing the rheological test within the linear viscoelasticity region (LVR), but the data that are measured are not directly useful for processing, as the required temperature lies between 180 – 195 °C. In order to obtain the WPC viscosity at such temperatures, a model that uses the WPC viscosity measured at 170 °C at different fibers quantity and of neat polypropylene viscosity measured at various temperatures has been proposed. These measurements allowed to obtain shift factors useful to estimate the WPC viscosity at any temperature and percentage of fibers.The aim of this work has been to validate such a model using an in – line rheometer directly connected to a single screw extruder. With this apparatus, 30% and 70% w...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.