Abstract

In-line oxygen sensors have been developed for the glass melt and for the float bath. Glass melt oxygen sensors are used for the continuous monitoring of the oxidation state (or redox) of the glass melt and are very important for the control of many glass melt and glass product properties such as radiative heat transfer, fining, foaming, forming and optical characteristics. Too high oxygen levels in the float bath can be prevented by using both oxygen sensors in the tin melt and the atmosphere above it. Oxygen related defects on the glass sheet surface such as dross, tin pick-up, bloom and tin drips are reduced or even prevented. Moreover, expensive hydrogen gas can be saved by a more effective dosage.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.