Abstract

Electrochemical aptasensors have been extensively used to quantify food contaminants (e.g., mycotoxin) by using high-affinity aptamer for target recognition. Yet, analytical performance of aptasensors using different aptamers can be varied for the same target. Here, four aptamers with different sequences (i.e., A22, A34, A42, and A45) of patulin (PAT) were selected to estimate sensing behaviors at electrodes with electrochemical (EC) and photoelectrochemical (PEC) assays. Synergistic effect of steric hindrance and electron transfer distance was found to significantly affect EC and PEC response for PAT at aptasensors fabricated with A22, A34, A42, or A45. Eventually, A22 emerged to be the optimal aptamer for aptasensing, despite the highest affinity of A42 to PAT. The A22-based EC-PEC dual-mode ratiometric aptasensor offered a linear range of 50 fg mL−1 – 500 ng mL−1 with a detection limit of 30 fg mL−1 for PAT, and it was applied to apple product (i.e., juice, puree) analysis.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.