The two current probes measurement method was employed by other researchers to measure the radio-frequency impedance of AC power mains. In this paper, with a modified measurement setup, the method is extended to measure the common-mode (CM) impedance of a CM choke under in-circuit condition. With a premeasurement characterization process, the effect of the measurement setup can be determined and eliminated. The proposed measurement provides a more realistic assessment of the CM impedance characteristic of any CM choke under actual operating condition.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.