Abstract
ABSTRACTAluminium-silicon alloying is applied to dislocation-containing FZ silicon samples in order to verify if this external gettering technique is able to remove impurities trapped by these defects. Samples were scratched (front surface), bent and annealed at 750°C for 6h in order to create dislocation arrays. Standard samples and also nickel contaminated samples were investigated by light beam induced current (LBIC) mapping technique before and after alloying at 900°C for 4h with a 1 μm thick aluminium layer deposited on the backside. The LBIC technique detects the features of the dislocation array in agreement with X ray topographs. In the standard samples, the contrast is relatedto an inadvertent contamination of the samples and disappears after gettering. In the contaminated samples, dislocation contrast is higher, the aluminium treatment attenuates strongly the dislocations electrical activity but not so neatly as for the standard samples. This result is explained by the possible microprecipitation of nickel at dislocations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.