Abstract

Experience shows the occurrence of situations when the measurements of impulse noise parameters are made with measurement equipment unsuitable for such conditions. The results of using such equipment were compared with the results of using equipment with a sufficiently large upper limit of the measurement range. The analysis was carried out on the example of noise generated during shots from a Mossberg smooth-bore shotgun and AKM rifle, as well as produced in the forge. The use of the unsuitable equipment allowed to indicate the exceeding of the exposure limit value of the peak value of the signal (LC peak), but this is not always possible when determining the energy properties of the signal (L EX,8h). While the inadequate properties of the measurement equipment will generally not prevent the conclusion that noise in a particular workplace is hazardous to hearing, the results of measurements cannot be used to select hearing protectors.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.