Abstract
PurposeThe purpose of this paper is to recover the deficiency of existing tie force (TF) methods by considering the decrease in section strength due to cracking and by selecting limit state of collapse according to section properties.Design/methodology/approachA substructure is selected by isolating the connected beams from the entire structure. For interior joints, the TFs in the orthogonal beams are obtained by catenary action. For corner joints, the TFs are assessed by beam action. For edge joints, however, the resistance is gained by greater of the resistance under catenary action for periphery beams and beam action for all the connecting beams in both directions. For catenary action, the TF capacities must satisfy Equation (20). On the other hand, for beam action, the TF must satisfy Equation (16), while R is calculated from Equation (17). In the case where the length of the connecting beams is similar, Equation (19) can be used.FindingsClosed form solutions are available for TFs on both beam and catenary stages.Originality/valueThe proposed formulation makes designing more practical and convenient. However, the proposed formulation had good agreement with experimental results.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.