Abstract
ABSTRACT Recent test data have shown that the Knelson concentrator can provide a more efficient separation than froth flotation when cleaning coal in the 150 × 25 µm particle size range. To further improve the performance of this enhanced gravity separator, air bubbles were injected into the feed stream in an attempt to decrease the apparent density of the coal particles due to the formation of bubble-coal particle agglomerates. The test data showed that air injection had a significant impact on operating characteristics and separation performance. Coal recovery was increased by 10 to 20 absolute percentage points, while a 2 percentage point drop in the minimum product ash content was also achieved.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.