Abstract
The thiol (Cys34) content of human serum albumin (HSA-SH) decreases during oxidative and carbonyl stress and, therefore, could represent a useful parameter in clinical practice. Nevertheless, the reliability of HSA-thiol determination with Ellman’s method depends on the purity of isolated HSA. Determination of total serum thiols (mmol/L) and HSA-SH content (mmol -SH/mmol HSA) after HSA isolation from diabetic patient and control sera by a two-step precipitation with ammonium sulfate (AS), as well as HSA-SH contribution (%) to total serum thiols, was assessed. Purity and yield of isolated HSA were monitored spectrophotometrically and by native polyacrylamide gel electrophoresis. Precipitation of HSA from serum via a two-step method with AS produced HSA with 91.9±3.6% purity and 69.7±4.4% yield, allowing for precise (relative standard deviation of 3.2%) and reliable (comparing with total serum thiols) measurement of HSA-SH content with DTNB [5,5′-dithiobis-(2-nitrobenzoic acid)]. The content of the HSA-SH group in patients with type 2 diabetes was significantly (P<0.05) lower compared with that of the healthy cohort (0.483±0.067 vs. 0.561±0.054mmol -SH/mmol HSA). Because the proposed method of HSA isolation is simple, time-efficient, and technically less demanding, and it also enables reliable determination of HSA-SH content, it is suitable for clinical practice.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.