Abstract

Reliability of cable lines in hot climate is determined by the climatic characteristics of cables and wires, which include: long-term and short-term heat resistance, cold resistance, moisture resistance, resistance to cyclic exposure to temperatures and solar radiation, ozone resistance, etc. This article considers the main impacts of environmental factors: high temperatures, solar radiation, which, as practice shows, lead to irreversible deterioration of the electrical and mechanical properties of cable products. The result of climatic impacts in the Central Asian region, in hot climate conditions, is the aging of both insulation and protective coverings, which leads to irreversible change in the mechanical and electrical properties of the used polymers due to the loss of elasticity of the extruded material and its subsequent cracking, turning into cracks. The assessment of the possibility of long-term operation of the used polymer was carried out according to the polyethylene oxidation period, which determines the time of natural preservation of various types of cables during the period of their operation. The research was carried out on samples of cables stored under a canopy in wooden boxes, protected from sunlight and precipitation, by measuring criterion parameters with strict compliance with the established norms. Thus, the proposed solution for increasing the reliability of cable lines consists of debugging the technological process of applying insulation and sheathing, in which the extrusion of the polymer mass is carried out by technique that minimizes the ingress of contamination. Review of the results showed that extrusion line improvement would provide possibility of increasing reliability in the operation of cable products under the impact of climatic factors of the Central Asian region due to the reduced aging of insulation.

Highlights

  • Reliable operation of cable lines in hot climate is usually determined by the climatic characteristics of cables and wires, which include: long-term and short-term heat resistance, cold resistance, moisture resistance, resistance to cyclic exposure to temperatures and solar radiation, ozone resistance, etc

  • As a result of the climatic impact in the Central Asian region, this is rapid aging of both insulation and protective shells, which leads to an irreversible change in the performance characteristics of used polymers: loss of elasticity of the extruded material and its subsequent cracking, which turns into cracks

  • Reliability of cable lines is determined by the climatic characteristics of cables and wires, which include long and short-term heat resistance, cold resistance, moisture resistance, resistance to cyclical effects of temperature and solar radiation, ozone resistance, etc

Read more

Summary

Introduction

Reliable operation of cable lines in hot climate is usually determined by the climatic characteristics of cables and wires, which include: long-term and short-term heat resistance, cold resistance, moisture resistance, resistance to cyclic exposure to temperatures and solar radiation, ozone resistance, etc. Reliability of cable lines is determined by the climatic characteristics of cables and wires, which include long and short-term heat resistance, cold resistance, moisture resistance, resistance to cyclical effects of temperature and solar radiation, ozone resistance, etc. There is another problem of high ambient temperatures influence on the smooth operation of electrical systems, namely the temperature of the earth surface during summer. The tabular data are given, taking into account the temperature of the XLPE insulation, which does not exceed the permissible temperature [1]

Operation characteristics
Findings
Dielectric permeability
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call