Abstract

With increasing emphasis on energy and efficiency, a major concern for Voltage Regulator Modules (VRMs) is their operation during light-loads. VRMs are usually optimized at one load level, which is in the 50 - 100% range. Therefore operating at load levels significantly lower than this produces inefficient operation, resulting in reduced battery life (in laptops) or increased electricity costs. This work proposes switching off one or more parallel inductors according to the load level, thus eliminating associated inductor core loss and significantly reducing connected MOSFET losses. Using this technique it is shown that an improvement of up to 17% in efficiency is achieved at 10% of full-load for a typical VRM solution.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.