Abstract
In this work, the effects of magnetic field induction on electrical and electromagnetic shielding properties of conductive silicon rubbers (CSRs) filled with Ni-coated carbon fibres (Ni/CFs) have been investigated. When the magnetic field intensity is above the threshold value of 0.10 T during the vulcanisation, it is beneficial to their electrical property that the volume resistivity decreases from 48.7 Ω·cm to 1.57 Ω·cm, owing to the orientation alignment of Ni/CFs in CSRs filled with Ni/CFs (40 phr). Moreover, with the aids of magnetic field induction, the prepared CSRs with lower amount of Ni-CF filler can receive better electromagnetic shielding of 65 dB in 500 MHz–3 GHz, which reduce cost effectively. This vulcanisation process shows promises for various applications in power transmission and transformation industries.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.