Abstract

The British Thoracic Society (BTS) Acute Non-Invasive Ventilation (NIV) standards state all patients who require acute NIV should be initiated on NIV within two hours of hospital admission. The delivery of acute NIV is a time critical intervention as prompt application of acute NIV substantially reduces mortality for patients with acute hypercapnic respiratory failure. This audit aimed to assess the number of patients for whom there is a delay in the initiation of acute NIV. We also assessed the outcome of admission for patients started on acute NIV. Data was collected on patients admitted to Kings Mill Hospital for acute NIV between 1/2/2019 and 31/3/2019. Awareness and knowledge of acute NIV was highlighted as an area for improvement. E-learning packages on 'Acute NIV' were designed and sent to medical-staff. The audit was repeated for patients admitted for acute NIV between 1/2/2020 and 31/3/2020 and analysed using chi-square tests. 25 patients were included in the initial audit and 30 patients in the re-audit. Prior to intervention 31% of patients had a delay in the initiation of acute NIV, which increased to 77% post-intervention (p <0.0001). Prior to intervention there was a mortality rate of 17% and a mortality rate of 13% post-intervention (p >0.05). Further work is required to ensure the sustained delivery of acute NIV to BTS standards, however variable achievements in the targets does not seem to have a significant adverse effect on patient outcomes.