Abstract

ABSTRACT The activPAL is a valid measure of step counts and posture, but its ability to determine physical activity intensity is unclear. This study tested the criterion validity of the activPAL using its built-in linear cadence-metabolic equivalents (METs) equation (activPAL-linear) versus an individualized height-adjusted curvilinear cadence-METs equation (activPAL-curvilinear) to estimate intensity-related physical activity. Forty adults (25±6 years, 23.3±4.1 kg/m2) wore an activPAL during a 7-stage progressive treadmill walking protocol (criterion: indirect calorimetry). A sub-sample (n=32) wore the device during free-living conditions for 7-days (criterion: PiezoRxD monitor). In the laboratory, the activPAL-linear overestimated METs during slow walking (1.5–3.0 miles•hour−1) but underestimated METs during fast walking (3.5–4.5 miles•hour−1) (all, p<0.001). In the free-living condition, the activPAL-linear overestimated time in light-intensity activity and underestimated moderate-intensity activity (both, p<0.001), but did not register any vigorous-intensity activity. In contrast, the activPAL-curvilinear estimated values statistically equivalent to indirect calorimetry for treadmill stages 1–6 (1.5–4.0 miles•hour−1) and to the PiezoRxD determined light- and moderate-intensity activity during free-living. We present a simple, data processing technique that uses an alternative curvilinear cadence-MET equation that improves the ability of the activPAL to measure intensity-related physical activity in both laboratory and free-living settings.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call