Abstract

Echocardiographic calculation of effective orifice area (EOA) after transcatheter aortic valve replacement is integral to the assessment of transcatheter heart valve (THV) function. The aim of this study was to determine the most accurate method for calculating the EOA of the Edwards SAPIEN and SAPIEN XT THVs. One hundred intraprocedural transesophageal echocardiograms were analyzed. To calculate the post-transcatheter aortic valve replacement left ventricular outflow tract (LVOT) stroke volume (SV), four diameters were measured using two-dimensional echocardiography: (1) baseline LVOT diameter (LVOTd_PRE), (2) postimplantation LVOT diameter, (3) native aortic annular diameter, and (4) THV in-stent diameter. Four corresponding areas were planimetered by three-dimensional echocardiography. Two LVOT velocity-time integrals (VTI) were measured with the pulsed-wave Doppler sample volume at (1) the proximal (apical) edge of the valve stent or (2) within the valve stent at the level of the THV cusps. LVOT velocity-time integral with the sample volume at the proximal edge of the valve stent was used with the LVOT and aortic annular measurements above, whereas in-stent VTI was paired with the in-stent THV diameter to yield eight different SVs. Right ventricular outflow tract (RVOT) SV was calculated using RVOT diameter and RVOT VTI and was used as the primary comparator. Transaortic VTI was obtained by continuous-wave Doppler, and EOA calculations using each SV measurement were compared with (1) EOA calculated using RVOTSV and (2) planimetered aortic valve area using three-dimensional echocardiography (AVAplanimetry3D). Post-transcatheter aortic valve replacement EOA calculated using LVOTd_PRE was not significantly different from EOA calculated using RVOTSV (1.88±0.33 vs 1.86±0.39cm(2), P=.36) or from AVAplanimetry3D (1.85±0.28, P=.38, n=34). All other two-dimensional EOA calculations were statistically larger than EOA calculated using RVOTSV. All three-dimensional echocardiography-based EOA calculations were statistically different from AVAplanimetry3D. The most accurate EOA after implantation of a balloon-expandable THV is calculated using preimplantation LVOT diameter and VTI.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.