Abstract

Test effectiveness of a test-per-scan built-in self-test (BIST) scheme is highly dependent on the length and number of scan chains. Fewer cycles are used to capture test responses when the length of the scan chains increases and the total number of clock cycles is fixed. Another important feature of the test-per-scan BIST scheme is that test responses of the circuit at the inputs of the scan flip-flops are not observable during the shift cycles. A new scan architecture is proposed to make a scan-based circuit more observable. The scan chain is partitioned into multiple segments. Multiple capture cycles are inserted to receive test responses during the shift cycles compared to the test-per-scan test scheme. Unlike other BIST schemes using multiple capture cycles after the shift cycles, our method inserts multiple capture cycles inside the shift cycles, but not after the shift cycles. Unlike the previous method that drives multiple scan segments by a single scan-in signal, the proposed method uses a new architecture to control all scan segments by different signals. Sufficient experimental results are presented to demonstrate the effectiveness of the method.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.