Abstract

Patient and procedure verification, or the time-out process (TOP), is considered one of the most vital components of patient safety. It has long been a focus of intervention in the surgical community and recently was incorporated into the American Society for Gastrointestinal Endoscopy guidelines for safety in the GI endoscopy unit. The TOP has had limited attention in the endoscopy literature but remains an area for improvement in clinical endoscopy practice. The aim of this study was to identify barriers and improve TOP compliance rates in our endoscopy unit using remote video auditing (RVA). This was a single-center, prospective, pilot initiative in an endoscopy unit at a tertiary care academic medical center. Video cameras with offsite monitoring were installed in each procedure room in our endoscopy suite in November 2016. Baseline TOP compliance rates were audited with RVA over a 2-month period. A multidisciplinary quality improvement team reviewed the data, identified barriers to the TOP, and implemented actionable items in January 2017. TOP compliance rates were again monitored via RVA, and data were collected through October 2018. Pre- and postintervention TOP compliance rates were compared. Over the baseline period, 692 procedures were audited and TOP compliance documented. Baseline TOP compliance rate was 69.6%. Identifiable barriers to TOP compliance included a lack of designated team member to lead TOP, inconsistent documentation of TOP, irrelevant safety checklist items not applicable to endoscopic procedures, and lack of patient safety culture. Actionable items implemented in response to these barriers included designation of a TOP leader, visual indication of initiation of TOP, creation of a concise endoscopy-specific safety checklist, and formal notification/education of the entire endoscopy team. Postintervention TOP compliance rates were then audited from January 2017 to October 2018 and included 12,008 procedures. The mean TOP compliance rate significantly improved from baseline (95.3% vs 69.6%; 95% confidence interval, 22.4-29.3; P< .0001). Additionally, the improvement was maintained throughout the entire postintervention observation period. TOP compliance rates significantly improved in our endoscopy unit through the use of RVA and implementation of 4 actionable items. Future studies should evaluate the reproducibility of this method in other endoscopy units.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.