Abstract Background Cardiac arrhythmias are a significant cause of morbidity and mortality worldwide. The characterization of cardiac tissue's electrophysiological substrate is crucial for the diagnosis and treatment of these conditions. High-density (HD) electrode arrays, such as the Advisor™ HD Grid Mapping Catheter and Sensor Enabled™ (SE), are commonly used to examine cardiac tissue locally and create activation maps. However, the current method for reconstructing omnipolar EGMs, a novel technique claimed to be orientation-independent, has limitations. The enhancement of this reconstruction methodology has the potential to improve the accuracy and reliability of electrophysiological mapping. This, in turn, can have a positive impact on patients suffering from cardiac arrhythmias, ultimately leading to better clinical outcomes. Purpose We propose a novel reconstruction method to estimate omnipolar EGM that overcomes the angle dependence weakness of the current method to enhance the reconstruction of electrophysiological signals. Methodology Prior experiments were conducted on isolated rabbit hearts using a 128-electrode array with electrodes spaced 1mm apart over the ventricular epicardium. Four-electrode cliques were designed from these experiments, with different inter-electrode distances as depicted in Figure 1A, to reconstruct the current and novel omnipolar configurations. Metrics were designed to assess the quality of the electrogram signals, including the bipolar loop area and the ratio of the bipolar components of the omnipole (see fig. 2). The bipoles were calculated from unipolar electrograms, and the signal was corrected with a 45º offset in the cross. The propagation angle was then detected, and the local activation time (LAT) was estimated. Results In the bipole plots, it was observed that the morphology of the bipolar loop becomes distorted with an increase in the inter-electrode distance, becoming thinner for distances less than 2mm. There is a direct relation between the areas in the bipolar loop and the inter-electrode distance (see Figure 2A). Furthermore, the values of the area in the cross are always comparable to the best-performing triangular clique. For the ratio of bipoles, the relation is inversely related to distance (see Figure 2B). Similarly, the performance of the cross is comparable to the best-performing triangular omnipole. Conclusion This study highlights the importance of accurate reconstruction of omnipolar EGMs for the diagnosis and treatment of cardiac arrhythmias. To achieve precise reconstruction, inter-electrode distances smaller than 2mm are recommended. The proposed reconstruction method based on the cross configuration is more accurate and robust to wavefront propagation, provided that the recommended distance criterion is met. This study opens up new possibilities for the design of new devices and practices in the clinic.Figure 1Figure 2
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.