Abstract

Mitotic count in breast cancer is an important prognostic marker. Unfortunately, substantial inter- and intraobserver variation exists when pathologists manually count mitotic figures. To alleviate this problem, we developed a new technique incorporating both haematoxylin and eosin (H&E) and phosphorylated histone H3 (PHH3), a marker highly specific to mitotic figures, and compared it to visual scoring of mitotic figures using H&E only. Two full-face sections from 97 cases were cut, one stained with H&E only, and the other was stained with PHH3 and counterstained with H&E (PHH3-H&E). Counting mitoses using PHH3-H&E was compared to traditional mitoses scoring using H&E in terms of reproducibility, scoring time, and the ability to detect mitosis hotspots. We assessed the agreement between manual and image analysis-assisted scoring of mitotic figures using H&E and PHH3-H&E-stained cells. The diagnostic performance of PHH3 in detecting mitotic figures in terms of sensitivity and specificity was measured. Finally, PHH3 replaced the mitosis score in a multivariate analysis to assess its significance. Pathologists detected significantly higher mitotic figures using the PHH3-H&E (median ± SD, 20 ± 33) compared with H&E alone (median ± SD, 16 ± 25), P < 0.001. The concordance between pathologists in identifying mitotic figures was highest when using the dual PHH3-H&E technique; in addition, it highlighted mitotic figures at low power, allowing better agreement on choosing the hotspot area (k=0.842) in comparison with standard H&E (k=0.625). A better agreement between image analysis-assisted software and the human eye was observed for PHH3-stained mitotic figures. When the mitosis score was replaced with PHH3 in a Cox regression model with other grade components, PHH3 was an independent predictor of survival (hazard ratio [HR] 5.66, 95% confidence interval[CI] 1.92-16.69; P=0.002), and even showed a more significant association with breast cancer-specific survival (BCSS) than mitosis (HR 3.63, 95% CI 1.49-8.86; P=0.005) and Ki67 (P=0.27). Using PHH3-H&E-stained slides can reliably be used in routine scoring of mitotic figures and integrating both techniques will compensate for each other's limitations and improve diagnostic accuracy, quality, and precision.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.