Abstract

Accurately fitting diffusion-time-dependent diffusion MRI (td-dMRI) models poses challenges due to complex and nonlinear formulas, signal noise, and limited clinical data acquisition. Introduce a Bayesian methodology to refine microstructural fitting within the IMPULSED (Imaging Microstructural Parameters Using Limited Spectrally Edited Diffusion) model and optimize the prior distribution within the Bayesian framework. Retrospective. Involving 69 pediatric patients (median age 6 years, interquartile range [IQR] 3-9 years, 61% male) with 41 low-grade and 28 high-grade gliomas, of which 76.8% were identified within the brainstem or cerebellum. 3 T, oscillating gradient spin-echo (OGSE) and pulsed gradient spin-echo (PGSE). The Bayesian method's performance in fitting cell diameter ( ), intracellular volume fraction ( ), and extracellular diffusion coefficient ( ) was compared against the NLLS method, considering simulated and experimental data. The tumor region-of-interest (ROI) were manually delineated on the b0 images. The diagnostic performance in distinguishing high- and low-grade gliomas was assessed, and fitting accuracy was validated against H&E-stained pathology. T-test, receiver operating curve (ROC), area under the curve (AUC) and DeLong's test were conducted. Significance considered at P < 0.05. Bayesian methodology manifested increased accuracy with robust estimates in simulation (RMSE decreased by 29.6%, 40.9%, 13.6%, and STD decreased by 29.2%, 43.5%, and 24.0%, respectively for , , and compared to NLLS), indicating fewer outliers and reduced error. Diagnostic performance for tumor grade was similar in both methods, however, Bayesian method generated smoother microstructural maps (outliers ratio decreased by 45.3% ± 19.4%) and a marginal enhancement in correlation with H&E staining result (r = 0.721 for compared to r = 0.698 using NLLS, P = 0.5764). The proposed Bayesian method substantially enhances the accuracy and robustness of IMPULSED model estimation, suggesting its potential clinical utility in characterizing cellular microstructure. 3 TECHNICAL EFFICACY: Stage 1.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.