Abstract

PurposeManually identifying geographic atrophy (GA) presence and location on OCT volume scans can be challenging and time consuming. This study developed a deep learning model simultaneously (1) to perform automated detection of GA presence or absence from OCT volume scans and (2) to provide interpretability by demonstrating which regions of which B-scans show GA.DesignMed-XAI-Net, an interpretable deep learning model was developed to detect GA presence or absence from OCT volume scans using only volume scan labels, as well as to interpret the most relevant B-scans and B-scan regions.ParticipantsOne thousand two hundred eighty-four OCT volume scans (each containing 100 B-scans) from 311 participants, including 321 volumes with GA and 963 volumes without GA.MethodsMed-XAI-Net simulates the human diagnostic process by using a region-attention module to locate the most relevant region in each B-scan, followed by an image-attention module to select the most relevant B-scans for classifying GA presence or absence in each OCT volume scan. Med-XAI-Net was trained and tested (80% and 20% participants, respectively) using gold standard volume scan labels from human expert graders.Main Outcome MeasuresAccuracy, area under the receiver operating characteristic (ROC) curve, F1 score, sensitivity, and specificity.ResultsIn the detection of GA presence or absence, Med-XAI-Net obtained superior performance (91.5%, 93.5%, 82.3%, 82.8%, and 94.6% on accuracy, area under the ROC curve, F1 score, sensitivity, and specificity, respectively) to that of 2 other state-of-the-art deep learning methods. The performance of ophthalmologists grading only the 5 B-scans selected by Med-XAI-Net as most relevant (95.7%, 95.4%, 91.2%, and 100%, respectively) was almost identical to that of ophthalmologists grading all volume scans (96.0%, 95.7%, 91.8%, and 100%, respectively). Even grading only 1 region in 1 B-scan, the ophthalmologists demonstrated moderately high performance (89.0%, 87.4%, 77.6%, and 100%, respectively).ConclusionsDespite using ground truth labels during training at the volume scan level only, Med-XAI-Net was effective in locating GA in B-scans and selecting relevant B-scans within each volume scan for GA diagnosis. These results illustrate the strengths of Med-XAI-Net in interpreting which regions and B-scans contribute to GA detection in the volume scan.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.