Abstract

Falling film evaporators, due to their high heat transfer coefficients, low energy loss, rather a low holdup time, and the ability to handle high capacities have broad applications in food industries. Thus, this kind of evaporator is being used in the production of temperature sensitive compounds such as syrups. In this study, through modelling of the falling film evaporator with the use of Computational Fluid Dynamics (CFD) we have tried to investigate the effect of adding flow turbulator (baffles) on the inner side of the tubes and assess the key parameters for increasing the efficiency of the evaporator. The simulation was conducted using ANSYS FUENT (v 0.16.0). Results indicate that placing baffles would have a significant effect on increasing evaporator efficiency. The results of the parametric study showed that by installing baffles, the amount of juice evaporation rate can be increased, however, both the evaporator length and volume fraction can be reduced. The results showed that the heat transfer coefficient has increased from 10000 W/m2 °C in the case of the typical evaporator to 25000 W/m2 °C in the case of a baffled tube wall.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.