Abstract
Improvement of sludge dewaterability is crucial for reducing the costs of sludge disposal in wastewater treatment plants. This study presents a novel method based on combined conditioning with zero-valent iron (ZVI) and hydrogen peroxide (HP) at pH 2.0 to improve dewaterability of a full-scale waste activated sludge (WAS). The combination of ZVI (0–750mg/L) and HP (0–750mg/L) at pH 2.0 substantially improved the WAS dewaterability due to Fenton-like reactions. The highest improvement in WAS dewaterability was attained at 500mg ZVI/L and 250mg HP/L, when the capillary suction time of the WAS was reduced by approximately 50%. Particle size distribution indicated that the sludge flocs were decomposed after conditioning. Economic analysis showed that combined conditioning with ZVI and HP was a more economically favorable method for improving WAS dewaterability than the classical Fenton reaction based method initiated by ferrous salts and HP.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.