Abstract
AbstractA method using 1,10-phenanthroline (phen) to quantify Fe(II) and total Fe in nonrefractory minerals was modified to improve the accuracy and precision and to eliminate the inconvenience of performing much of the analysis under darkroom conditions. Reagents were combined to minimize solution-handling errors, volumes of the reagent additions were determined gravimetrically and the acid-matrix solution was preheated to near-boiling before sample contact. The darkness requirement, which stems from the photoreduction of Fe(III) to Fe(II) in the presence of phen, was eliminated by the use of opaque amber-colored high-density-polyethylene bottles during the digestion step and for storage of the digestate and subsequent dilutions before Fe(II) analysis. Reduction of Fe(III) for total-Fe analysis was accomplished either by exposure to light from a Hg-vapor lamp or by reaction with hydroxylamine, NH2OH. Although the minimum periods required for adequate reduction ranged from 1.5 to 4 h, the optimum reduction periods were between 6 and 10 h. When standard samples containing Fe(II) and MnCl2 were digested and analyzed for total-Fe using the light treatment (with incidental heating to 35–45 °C), significant decreases and in some instances, oscillations, in absorptivity were obtained. Similar experiments with NH2OH, or with CrCl3 showed no effect. The absorptivity of most digestates stored in opaque bottles was stable for at least 2 weeks, although digestates with Mn concentrations above 3 µg mL−1 showed proportional decreases in absorptivity. Analysis of 8 geochemical reference materials by the modified method (using NH2OH) yielded excellent agreement with published values and a mean relative standard deviation of 0.6%. Total-Fe results obtained using the light treatment, however, were generally lower (∼2% relative) than the NH2OH values, although this difference decreased with longer irradiation periods. Use of NH2OH was deemed preferable because it was simpler, faster, minimized interferences from Mn and eliminated the need for specialized apparatus. Lastly, MICA Fe was shown to be unreliable as a primary reference material for Fe(II) determinations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.