The Italian National Annex (NA) to EN ISO 52016-1 is aimed at improving the simplified hourly calculation method of the building thermal performance assessment by introducing different modelling options. The present work deepens the influence of the Italian NA improved method on the thermal energy needs for heating and cooling of a residential building-type in two different climate zones. In particular, the Italian NA improved options are applied one-at-the-time, and their effect is evaluated in comparison with the EN ISO 52016-1 standard method. The use of solar angle and time dependent correction factors for the total solar energy transmittance of glazing proved to be the most sensitive modelling option, among those analysed. Negligible variations were instead reported for the other tested options.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.