Abstract

Oil-free reciprocating pump has been developed for tritium services at Tritium Process Laboratory (TPL) in Japan Atomic Energy Agency, and used for more than 20 years without any big trouble. One disadvantage of the above reciprocating pump is rather high ultimate pressure and drastically decreasing of the pumping performance at the lower suction pressure. The main reason would be that the check valves could not open enough at lower suction pressure, which are installed in the piston of the pump. In order to improve this disadvantage, solenoid valves option was tested instead of the check valves. Intentional opening & closing of the solenoid valves, linked with reciprocating motion cycle of the pump, improved more than one order of the ultimate pressure drastically. High evacuation performance was also demonstrated by the combination of molecular DRUG pump and the improved reciprocating pump with solenoid valve.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.