Abstract

UVC (ultrathin vapor chamber) simultaneously has a high heat-conducting property, excellent temperature uniformity and simple structure. These advantages are very suitable for thermal management of the open-cathode PEMFC (proton exchange membrane fuel cell) stack. In this work, two-type UVCs with different appearances are integrated into a conventional PEMFC stack respectively. The effect of UVC on the output performance, thermal management and operating stability is investigated by the experiment combined with simulation. The results show that UVC can significantly increase the output voltage under high current density. In 35 A, the output voltage of the stack integrated the vertical UVC increases by 20.25% relative to the conventional stack. Thermal management is also improved by UVC. The highest temperature inside the stack decrease by 9 °C in 35 A, and the membrane temperature is decreased obviously. But it still exceeds the optimal operating temperature of open-cathode PEMFC stack due to the poor cooling type in the condensation side of UVC. UVC improves the operation stability of the stack and slows the deteriorative speed of output performance. This work hopes to attract more attention to the application of UVC on the thermal management of portable power sources used open-cathode PEMFC stack.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call