Abstract

Vortex generators, which consist of small blades, are applied to conical diffusers the divergence angles of which are 8, 12, 16, 20, and 30 deg, respectively. The area ratio of each diffuser is four. The experiment covers the influence of various parameters, such as the arrangement of blades, inlet boundary layer thickness, and location of vortex generators relative to the conical diffuser, on the pressure-recovery coefficient. The experiment shows that the vortex generators prevent the flow in a conical diffuser from separating up to a divergence angle of 16 deg, and that the pressure-recovery coefficient is approximately equal to that of conventional best conical diffusers.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.