Abstract

The relevance of the work is due to the need to improve methods for diagnosing high-voltage oil-filled voltage transformers with paper-oil electrical insulation, which makes it possible to solve the problems of monitoring the technical condition, finding the place and determining the causes of failure (malfunction), and predicting the technical condition of this equipment on the basis of appropriate diagnostic software. The aim of the work is to ensure the reliability of operation of high-voltage oil-filled voltage transformers with paper-oil electrical insulation by improving the method of their diagnosis based on the results of analyses of samples of mineral transformer oils by gas chromatography. In accordance with the research objective, the following tasks were solved: 1. Determine the content of such dissolved diagnostic components in samples of mineral transformer oils from high-voltage oil-filled voltage transformers of NKF-110, NKF-220, NKF-330 types as gases H2, CH4, C2H6, C2H4, C2H2, CO, CO2, O2, N2; additive "Ionol"; furan compounds (2-furyl alcohol; 2-furfural; 2-acetylfuran; 5-methyl-2-furfural) and the sum of their concentrations. 2. The basic procedures for diagnosing high-voltage oil-filled voltage transformers based on the results of analyses of mineral transformer oil samples with the determination of the content of dissolved diagnostic components in them were improved. For the diagnosis of high-voltage oil-filled voltage transformers based on the results of gas chromatographic analyses of samples of mineral transformer oils from this equipment, it is recommended to use the following methods: "Limit level of concentrations", "Tabular method", "Graphic images of defects", "ETRA", "Duval triangle", "Visual inspection after disassembly of high-voltage oil-filled voltage transformers". To determine the degree of danger of the development of the identified probable defects, the method of determining the "Relative growth rate of dissolved gas concentrations" can be used. The prospect of practical application of the results of the work is to ensure the reliability of operation of high-voltage oil-filled voltage transformers by improving the method of their diagnosis based on the results of analyses of samples of mineral transformer oils with simultaneous determination of the content of dissolved gases, the additive "Ionol", furan compounds by gas chromatography.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.