Abstract

Measurement of ocular irritancy is a necessary step in the safety evaluation of both industrial and consumer products. Assessment of the acute eye irritation potential is therefore part of the international regulatory requirements for testing of chemicals.The Bovine Corneal Opacity and Permeability (BCOP) assay is generally accepted as a valid in vitro alternative method to the Draize eye irritation test to detect corrosive and severe eye irritants (category 1), but has not proven sensitive enough to discriminate accurately moderate (category 2A/2B) to mild and non-irritating compounds. In the currently accepted BCOP assay, opacity is determined by the amount of light transmission through the cornea, and permeability is determined by the amount of sodium fluorescein dye that passes through all corneal cell layers. Both measurements are used to assign an In Vitro Irritancy Score (IVIS) for prediction of the in vivo ocular irritation potential of a test substance. Nowadays, opacity is measured by an OP-KIT opacitometer providing a center-weighted reading of light transmission by measuring changes in voltage when the transmission of white light passes through the cornea alters. As a consequence, this may underestimate opacity that develops as spots or heterogeneous opaque areas on the periphery of an isolated cornea.A prototype of a laser light-based opacitometer (PLLBO) allowing better measurement of opacities was developed by Van Goethem et al. (2010). This new device showed improved sensitivity to detect subtle changes in corneal transparency. Furthermore, the new opacitometer allowed the analysis of the complete corneal surface and was able to detect more efficiently opaque spots located along the sides of the excised corneas.A further improved prototype of the PLLBO was constructed in combination with a camera and a speckle noise reducer. Treatment conditions of the corneas in the cornea holders were optimized in order to mimic more the real in vivo situation. A set of test compounds with irritancy potencies especially in the mild and moderate range was tested. The improved LLBO showed some promising features which potentially could improve the usefulness of the BCOP test. Adaptation of cornea holders showed to be of limited value and only restricted to concentrations up to 15% which mimics more test conditions in industry.This 3-year research project was sponsored by the Stavros Niarchos Foundation (Greece).

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call