Abstract

This paper aims to improve the Total Harmonic Distortion (THD) performance, using a robust nonlinear controller, for a Grid-Side Energy Conversion System Based on LCL with damping resistance and without current sensor of the RC branch. The Sliding Mode Control (SMC) increases the THD because of the chattering phenomenon. But, the reduction of THD is considered as an advantage of the LCL filter. These harmonics are also decreased using the robust Fuzzy Sliding Mode Control (FSMC) and the elimination of RC sensor reduces the system cost. The DC bus voltage is controlled using the FSMC, taking into account the power loss. The evaluation of the reliability and performance of the proposed control system is achieved through a comparative study. The simulation and experimental results are carried out to validate the effectiveness of the proposed filter and control method of the grid-side converter. The proposed control system is capable of providing enhanced transient performance similar to that of the SMC, and keeps the steady-state harmonic spectra at the same level as those of the Vector Control (VC).

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call