Abstract
This paper investigates the application of the newly proposed Kronecker-based method for the reconstruction of compressively sensed electrocardiogram (ECG) signals. By applying the Kronecker-based method, ECG signal acquisition is done in smaller lengths. Collection of smaller length of ECG signals leads to fewer arithmetic operations during the compression phase. Instead of recovering individually in smaller lengths, recovery is done over several concatenated segments. This newly proposed recovery method improves the quality of the reconstructed signal when compared to the traditional recovery done without concatenation. Two random measurement matrices, namely the Gaussian and the Bernoulli matrices, are considered as sensing matrices in this study and the methodology is evaluated using 10 ECG signals acquired from the MIT arrhythmia database. The random Bernoulli matrix is found to provide better quality of recovered compressed ECG signal even with the traditional compressive recovery techniques. Recovery by the newly proposed Kroneckerbased method results in higher SNR in all the ECG signals when the compression ratio (CR) is 25% or 50% and when the CR is 75%, improvement is observed in majority of the ECG signals. Lower CRs provide better reconstruction than higher CRs. The Kronecker-based recovery method may be useful for wearable ECG devices.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.