Abstract

Increasing number of tall buildings in urban population caused development of tall building structures. One of the main lateral load resistant systems is core wall system in high-rise buildings. Core wall system has two important behavioral aspects where the first aspect is related to reduce the lateral displacement by the core bending resistance and the second is governed by increasing of the torsional resistance and core warping of buildings. In this study, the effects of closed section core in the last story have been considered on the behavior of models. Regarding this, all analyses were performed by ETABS 9.2.v software (Wilson and Habibullah). Consid- ering (a) drift and rotation of the core over height of buildings, (b) total and warping stress in the core body, (c) shear in beams due to warping stress, (d) effect of closing last story on period of models in various modes, (e) relative displacement between walls in the core system and (f) site effects in far and near field of fault by UBC97 spectra on base shear coefficient showed that the bimoment in open core is negative in the last quarter of building and it is similar to wall-frame structures. Furthermore, analytical results revealed that closed section core in the last story improves behavior of the last quarter of structure height, since closing of core section in the last story does not have significant effect on reducing base shear value in near and far field of active faults.

Highlights

  • The rapid growth of the urban population and consequent pressure on limited space has considerably influenced city residential development

  • Core wall system has two important behavioral aspects where the first aspect is related to reduce the lateral displacement by the core bending resistance and the second is governed by increasing of the torsional resistance and core warping of buildings

  • Considering (a) drift and rotation of the core over height of buildings, (b) total and warping stress in the core body, (c) shear in beams due to warping stress, (d) effect of closing last story on period of models in various modes, (e) relative displacement between walls in the core system and (f) site effects in far and near field of fault by UBC97 spectra on base shear coefficient showed that the bimoment in open core is negative in the last quarter of building and it is similar to wall–frame structures

Read more

Summary

Introduction

The rapid growth of the urban population and consequent pressure on limited space has considerably influenced city residential development. The high cost of land, the desire to avoid a continuous urban sprawl, and the need to preserve important agricultural production have all contributed to drive residential buildings upward. One of the design criteria for selecting a structural system in tall buildings is stability of these structures under the lateral loads. Shear walls may be used in internal, external or surround internal service areas to form cores (Stafford Smith and Coull 1991). The external appearance of building can be influenced by the internal placement of core walls (Stafford Smith and Coull 1991). In the early formative stages of design, quick structural appraisal of alternative shear walls will be required followed by careful design and analysis of the final arrangement (Stafford Smith and Coull 1991).

67 Page 2 of 12
Results and discussions
67 Page 4 of 12
67 Page 6 of 12
67 Page 8 of 12
67 Page 10 of 12
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call