Abstract

Anaerobic ponds are customarily designed as completely mixed reactors. However, evidence from experiments on full-scale facilities shows large deviations from ideal flow models, which in turn cause a reduced process performance. Thus, modified pilot scale anaerobic ponds receiving domestic sewage were developed and studied in parallel. A factorially designed experiment evaluated horizontal and vertical baffling, ponds fitted with cross-sectional plastic nets and a pond with a mixing pit. The hydrodynamic behaviour and process performance of these modified configurations were monitored for four flow rates (1.0, 1.2, 1.5 and 2.0 l/s). The results showed that baffling (vertical and horizontal) and the mixing pit configuration had the best hydrodynamic behaviours and removal efficiencies. Consequently, the development of high-rate anaerobic ponds, through improvements of hydrodynamic behaviour, seems feasible.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.